On April 8, 1996, Bushnell Fire Protection District responded to a fire incident at Cox Rd & Cucumber Hol, Fiatt, IL 61433, a farm use, livestock production property.
The alarm was received at 9:25 PM and 17 suppression personnel arrived at 9:36 PM. The time to arrive was 11 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | Cox Rd & Cucumber Hol, Fiatt, IL 61433 |
| County | Fulton County |
| State | IL |
| City | Fiatt |
| Zip Code | 61433 |
| Mixed Use | Farm use |
| Property Use | Livestock production |
| Census Tract | 000000 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 11 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | Mutual aid received |
| Alarms | 1 |
| District | 00R |
Personnel
| Support Personnel | 17 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Bushnell Fire Protection District |
| Department Type | Volunteer |
| Address | 410 N Dean St Bushnell, IL 61422-1229 |
| Phone | (309) 772-2416 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | IL_MH133_040896_960023_00 |
| State | Illinois |
| Fire Department ID | MH133 |
| Incident Date | 04/08/1996 |
| Incident Number | 960023 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Electrical Dist |
Legacy Fields
| Mutual Aid | Yes |
| Estimated Dollar Loss | 10,000 |
| Day of Week | Monday |
| Time In Service | 18:00 |
| Zip Code | 61433 |
| Method of Alarm | Telephone direct to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | Farm complex |
| Fixed Property Use | Agriculture; insufficient information available to classify further |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Structural Areas not classified above |
| Level of Fire Origin | Grade level to 9 feet above grade |
| Number of Stories | 1 |
| Equipment Involved in Ignition | Electrical Distribution Equipment not classified above |
| Form of Heat of Ignition | Heat from Electrical Equipment Arcing, Overloaded not classified above |
| Type of Material Ignited | Sawn wood |
| Form of Material Ignited | Structural member, framing |
| Ignition Factor | Misuse of Heat of Ignition not classified above |
| Construction Type | Unprotected ordinary, not qualifying 5 |
| Extent of Flame Damage | Extended beyond structure of origin |
| Extent of Smoke Damage | Confined to structure or origin |
| Form of Material Generating Most Smoke | Structural member, framing |
| Detector Performance | No detectors present |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Type of Material Generating Most Smoke | Sawn wood |
| Avenue of Smoke Travel | Opening in construction |
| Method of Extinguishment | Hand-laid hose line(s) with water from standpipe, hydrant, draft |
| Property Damage Classification | 10,000-24,999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | BASIC INDUSTRY, UTILITY, DEFENSE: UNCLASSIFIED |
Fire Report
Ignition
| Heat Source | Heat from powered equipment, other |
| Item First Ignited | Structural member or framing |
| Type of Material | Sawn wood, including all finished lumber |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Undetermined |
Number of Stories With Damage
| Story of Fire Origin | 79 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |