Summary
On August 21, 2006, Georgetown Fire Company, Inc. responded to a fire incident at E Pine St, Georgetown, DE 19947, a mercantile/business.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Type | Street address |
| Address | E Pine St, Georgetown, DE 19947 |
| County | Sussex County |
| State | DE |
| City | GEORGETOWN |
| Zip Code | 19947 |
| Property Use | Mercantile, business, other |
Response
| Incident Type | Fires in structures other than in a building |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 16 |
| EMS Personnel | 0 |
| Other Personnel | 2 |
Fire Department
| Name | Georgetown Fire Company, Inc. |
| Department Type | Volunteer |
| Address | 100 S Bedford St Georgetown, DE 19947-0077 |
| Phone | (302) 856-7700 |
| Website | https://georgetown77.com/ |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | DE_40077_8212006_0015694_0 |
| State | Delaware |
| Fire Department ID | 40077 |
| Incident Date | 08/21/2006 |
| Incident Number | 0015694 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Ignition
| Area of Origin | Wall surface: exterior |
| Heat Source | Hot ember or ash |
| Item First Ignited | Undetermined |
| Type of Material | Undetermined |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Abandoned or discarded materials or products |
Spread
| No Flame Spread/Same As First/Unknown | No |
| Item Contributing Most To Spread | Exterior wall covering or finish |
| Type Material Contributing Most To Spread | Plywood |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 2 |
| Building Height: Stories Below Grade | 0 |
| Building Length | 8 ft |
| Building Width | 20 ft |
| Number of Sprinklers Operating | 0 |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Acres Burned | 0 |
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Year | 0 |
Equipment
| Equipment Year | 0 |