On September 16, 2017, Midland Fire Department responded to a fire incident at Foundation Blvd, Midland, TX 79705, a non-mixed use, street/road in commercial area.

The alarm was received at 4:46 PM, 6 suppression personnel arrived at 4:53 PM, and the last unit was cleared at 5:36 PM. The time to arrive was 7 minutes and the total incident time was 50 minutes.

The following actions were taken during the incident: extinguish and salvage and overhaul.

Sponsored

Location


Type Intersection
Address Foundation Blvd, Midland, TX 79705
County Midland County
State TX
City Midland
Zip Code 79705
Mixed Use Not mixed use
Property Use Street or road in commercial area

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 7 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 50 minutes

Response


Incident Type Passenger vehicle fire
Department Station 05
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift B
Alarms 2
District 050

Personnel


Support Personnel 6
EMS Personnel 0
Other Personnel 0

Fire Department


Name Midland Fire Department
Department Type Career
Address 1500 W Wall St
Midland, TX 79701
Phone (432) 685-7436
Website http://www.midlandtexas.gov/

Actions Taken


First Action Taken Extinguish
Second Action Taken Salvage & overhaul

Losses *


Property Loss $15,000
Contents Loss $1,000
Property Value $15,000
Contents Value $1,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key TX_RV701_09162017_1711130_0
State Texas
Fire Department ID RV701
Incident Date 09/16/2017
Incident Number 1711130
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Ignition


Area of Origin Engine area, running gear, wheel area
Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Electrical wire, cable insulation
Type of Material Plastic
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Mechanical failure, malfunction, other

Structure


Not Residential No

Acres


Less Than One Acre No

Suppression Factors


Suppression Factor Flammable/combustible liquid hazard

Mobile Property Involved


Mobile Property Involved Involved in ignition and burned
Mobile Property Type Passenger car
Mobile Property Make Kia
Mobile Property Model Soul
Mobile Property Year 2014
Mobile Property State Texas
Mobile Property VIN Number KNDJP3A54E7015868