Incident Report – 01/25/1984 Old E.R. Road, Egegik, AK 99579
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On January 25, 1984, Anchorage Fire Department responded to a fire incident at Old E.R. Road, Egegik, AK 99579, a residential use, 1-or-2 family dwelling.
The alarm was received at 9:41 AM and personnel arrived at 12:00 AM. The time to arrive was 9 hours, 41 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | Old E.R. Road, Egegik, AK 99579 |
| County | Lake and Peninsula Borough |
| State | AK |
| City | Egegik |
| Zip Code | 99579 |
| Mixed Use | Residential use |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 9 hours, 41 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | Mutual aid received |
| Shift | 0 |
| Alarms | 0 |
| District | 000 |
Personnel
| Support Personnel | 0 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Anchorage Fire Department |
| Department Type | Career |
| Address | 100 E 4TH Ave Anchorage, AK 99501-2506 |
| Phone | (907) 267-4936 |
| Website | https://www.muni.org/departments/fire/pages/default.aspx |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | AK_23100_012584_400331_00 |
| State | Alaska |
| Fire Department ID | 23100 |
| Incident Date | 01/25/1984 |
| Incident Number | 400331 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Torches |
Legacy Fields
| Mutual Aid | Yes |
| Estimated Dollar Loss | 150,000 |
| Day of Week | Wednesday |
| Time In Service | 00:00 |
| Zip Code | 99579 |
| Method of Alarm | Telephone tie-line to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Ceiling and floor assembly, concealed floor/ceiling space |
| Level of Fire Origin | 10 to 19 feet above grade |
| Equipment Involved in Ignition | Equipment Involved in Ignition undetermined or not reported |
| Form of Heat of Ignition | Heat from properly operating electrical equipment |
| Type of Material Ignited | Sawn wood |
| Form of Material Ignited | Structural member, framing |
| Ignition Factor | Thawing |
| Construction Type | Unprotected wood frame not qualifying for 7 |
| Extent of Flame Damage | Confined to structure of origin |
| Extent of Smoke Damage | Confined to structure or origin |
| Detector Performance | No detectors present |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Type of Material Generating Most Smoke | Type of Material undetermined or not reported |
| Avenue of Smoke Travel | Most Significant Avenue of Smoke Travel undetermined or not reported |
| Method of Extinguishment | Method of Extinguishment, Control undetermined or not reported |
| Property Damage Classification | 50,000-249,999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | ONE- AND TWO-FAMILY DWELLING |
Fire Report
Ignition
| Heat Source | Radiated, conducted heat from operating equipment |
| Item First Ignited | Structural member or framing |
| Type of Material | Sawn wood, including all finished lumber |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Heat source too close to combustibles |
Structure
| Number of Residential Units | 1 |
Number of Stories With Damage
| Story of Fire Origin | 73 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Shipping container, mechanically moved |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |
Sponsored