Incident Report – 02/10/1997
Rr 1 Box 149, Arrowsmith, IL 61722

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On February 10, 1997, a fire department near Arrowsmith, IL responded to a fire incident at Rr 1 Box 149, Arrowsmith, IL 61722, a residential use, 1-or-2 family dwelling.

The alarm was received at 2:20 PM and 7 suppression personnel arrived at 2:25 PM. The time to arrive was 5 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address Rr 1 Box 149, Arrowsmith, IL 61722
County McLean County
State IL
City Arrowsmith
Zip Code 61722
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Census Tract 000000
Detector Alerted Occupants Detector alerted occupants

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

Response


Incident Type Fire in mobile prop. used as a fixed struc., other
Mutual Aid Given/Received Mutual aid received
Shift 1
Alarms 2

Personnel


Support Personnel 7
EMS Personnel Unknown
Other Personnel Unknown

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key IL_MK123_021097_970001_00
State Illinois
Fire Department ID MK123
Incident Date 02/10/1997
Incident Number 970001
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Unclassified elec malfunction

Legacy Fields


Mutual Aid Yes
Estimated Dollar Loss 10,000
Day of Week Monday
Time In Service 18:15
Zip Code 61722
Method of Alarm Direct report to a fire station (verbal)
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Motor craft (under 65 feet length overall)
Area of Fire Origin Kitchen, cooking area
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 1
Form of Heat of Ignition Short circuit arc from defective, worn insulation
Type of Material Ignited Hardboard, plywood
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Construction Type Unprotected wood frame not qualifying for 7
Extent of Flame Damage Confined to part of room or area of origin
Extent of Smoke Damage Confined to structure or origin
Form of Material Generating Most Smoke Structural member, framing
Detector Performance Detector(s) in the room or space of fire origin, and they operated
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Sawn wood
Avenue of Smoke Travel Corridor
Method of Extinguishment Portable extinguisher
Property Damage Classification 10,000-24,999 dollars
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Type of Material Plywood
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Short circuit arc from defective, worn insulation

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 24

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Operation Operated
Detector Effectiveness Undetermined

Mobile Property Involved


Mobile Property Type Tank truck - nonflammable cargo

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown

Hazmat Report

Cause of Release


Cause of Release Container or containment failure

Mobile Property


Legacy Fields

Make UNK
Type of Situation Found Structure fire
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property Type Motor craft (under 65 feet length overall)
Area of Fire Origin Kitchen, cooking area
Form of Heat of Ignition Short circuit arc from defective, worn insulation
Type of Material Ignited Hardboard, plywood
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Time of Arrival 14:20
Mutual Aid Yes
Dollar Loss $10,000