Report Icon

Incident Report – 02/27/1991
Rr 1, Cedar, IA 52543

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On February 27, 1991, a fire department near Cedar, IA responded to a fire incident at Rr 1, Cedar, IA 52543, a farm use, livestock production property.

The alarm was received at 6:45 AM and 5 suppression personnel arrived at 7:00 AM. The time to arrive was 15 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address Rr 1, Cedar, IA 52543
County Mahaska County
State IA
City Cedar
Zip Code 52543
Mixed Use Farm use
Property Use Livestock production
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 15 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Shift 1
Alarms 1
District 000

Personnel


Support Personnel 5
EMS Personnel Unknown
Other Personnel Unknown

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key IA_62003_022791_000003_00
State Iowa
Fire Department ID 62003
Incident Date 02/27/1991
Incident Number 000003
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Electrical Dist

Legacy Fields


Estimated Dollar Loss 0
Day of Week Wednesday
Zip Code 52543
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Farm complex
Fixed Property Use Piggery, hog production
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Structural Areas not classified above
Level of Fire Origin 10 to 19 feet above grade
Number of Stories 1
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Heat from Electrical Equipment Arcing, Overloaded; insufficient information available to classify further
Type of Material Ignited Sawn wood
Form of Material Ignited Interior wall covering, surface items permanently affixed to wall and door surface
Ignition Factor Short circuit, ground fault
Construction Type Unprotected wood frame not qualifying for 7
Extent of Flame Damage Confined to structure of origin
Extent of Smoke Damage Confined to structure or origin
Form of Material Generating Most Smoke Form of Material undetermined or not reported
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Type of Material undetermined or not reported
Avenue of Smoke Travel Most Significant Avenue of Smoke Travel undetermined or not reported
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification Undertermined
Occupancy Type Single or double occupancy
Occupancy Code BASIC INDUSTRY, UTILITY, DEFENSE: UNCLASSIFIED

Fire Report

Ignition


Heat Source Heat from powered equipment, other
Item First Ignited Interior wall covering excluding drapes, etc
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Undetermined

Number of Stories With Damage


Story of Fire Origin 79

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown
Sponsored