On April 5, 1991, Mapleton Fire Department responded to a fire incident at Rr 1, Mapleton, IA 51034, a vehicle parking area.

The alarm was received at 1:30 PM and 15 suppression personnel arrived at 1:40 PM. The time to arrive was 10 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address Rr 1, Mapleton, IA 51034
County Monona County
State IA
City Mapleton
Zip Code 51034
Property Use Vehicle parking area

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 10 minutes

Response


Incident Type Mobile property (vehicle) fire, other
Mutual Aid Given/Received None
Shift 0
Alarms 1
District 000

Personnel


Support Personnel 15
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Mapleton Fire Department
Department Type Volunteer
Address 102 S 2nd St
Mapleton, IA 51034
Phone (712) 881-2124

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key IA_67003_040591_000007_00
State Iowa
Fire Department ID 67003
Incident Date 04/05/1991
Incident Number 000007
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Electrical Dist

Legacy Fields


Estimated Dollar Loss 15,000
Day of Week Friday
Time In Service 13:55
Zip Code 51034
Method of Alarm Telephone tie-line to fire department
Type of Situation Found Vehicle fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Warehouse, storage complex
Fixed Property Use Heavy machine, equipment storage
Mobile Property type Tractor, harvester, picker
Area of Fire Origin Engine area, running gear, wheel area of transportation equipment
Level of Fire Origin Grade level to 9 feet above grade
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Heat from overloaded equipment
Type of Material Ignited Type of Material not classified above
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 10,000-24,999 dollars
Occupancy Type Multiple occupancy
Occupancy Code BASIC INDUSTRY, UTILITY, DEFENSE: UNCLASSIFIED

Fire Report

Ignition


Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Electrical wire, cable insulation
Type of Material Type of material first ignited, other
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Equipment overloaded

Number of Stories With Damage


Story of Fire Origin 83

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown

Hazmat Report

Cause of Release


Cause of Release Container or containment failure

Equipment Involved in Release


Equipment

Equipment Brand TRACTOR
Equipment Model WIRING

Legacy Fields

Type of Situation Found Vehicle fire
Complex Warehouse, storage complex
Fixed Property Use Heavy machine, equipment storage
Mobile Property Type Tractor, harvester, picker
Area of Fire Origin Engine area, running gear, wheel area of transportation equipment
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Heat from overloaded equipment
Type of Material Ignited Type of Material not classified above
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Dollar Loss $15,000

Mobile Property


Description

Model TRACTOR
Year 00

Legacy Fields

Type of Situation Found Vehicle fire
Complex Warehouse, storage complex
Fixed Property Use Heavy machine, equipment storage
Mobile Property Type Tractor, harvester, picker
Area of Fire Origin Engine area, running gear, wheel area of transportation equipment
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Heat from overloaded equipment
Type of Material Ignited Type of Material not classified above
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Time of Arrival 13:30
Dollar Loss $15,000
Sponsored