Incident Report – 08/13/1997 Rr 1,Bird Island,Mn, Ceylon, MN 56121
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On August 13, 1997, Franklin Fire Department responded to a fire incident at Rr 1,Bird Island,Mn, Ceylon, MN 56121, a farm use, livestock/poultry storage area.
The alarm was received at 12:00 AM and 11 suppression personnel arrived at 12:00 AM.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | Rr 1,Bird Island,Mn, Ceylon, MN 56121 |
| County | Martin County |
| State | MN |
| City | Ceylon |
| Zip Code | 56121 |
| Mixed Use | Farm use |
| Property Use | Livestock, poultry storage |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Alarms | 1 |
Personnel
| Support Personnel | 11 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Franklin Fire Department |
| Department Type | Volunteer |
| Address | PO Box 279 Franklin, MN 55333 |
| Phone | (507) 557-2259 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | MN_65105_081397_000005_00 |
| State | Minnesota |
| Fire Department ID | 65105 |
| Incident Date | 08/13/1997 |
| Incident Number | 000005 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Electrical Dist |
Legacy Fields
| Estimated Dollar Loss | 0 |
| Day of Week | Wednesday |
| Time In Service | 00:00 |
| Zip Code | 56121 |
| Method of Alarm | Telephone tie-line to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | Farm complex |
| Fixed Property Use | Barns, stables |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Area of Origin undetermined or not reported |
| Level of Fire Origin | Grade level to 9 feet above grade |
| Number of Stories | 1 |
| Equipment Involved in Ignition | Power switch gear, overcurrent protection devices |
| Form of Heat of Ignition | Unspecified short circuit arc |
| Type of Material Ignited | Wood, Paper not classified above |
| Form of Material Ignited | Exterior sidewall covering, surface, finish |
| Ignition Factor | Short circuit, ground fault |
| Construction Type | Unprotected wood frame not qualifying for 7 |
| Extent of Flame Damage | Extent of Flame Damage undetermined or not reported |
| Extent of Smoke Damage | Extent of Smoke Damage undetermined or not reported |
| Form of Material Generating Most Smoke | Form of Material undetermined or not reported |
| Detector Performance | No detectors present |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Type of Material Generating Most Smoke | Type of Material undetermined or not reported |
| Avenue of Smoke Travel | Most Significant Avenue of Smoke Travel undetermined or not reported |
| Method of Extinguishment | Preconnected hose line(s) with water carried in apparatus tanks |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | STORAGE PROPERTY: UNCLASSIFIED |
Fire Report
Ignition
| Heat Source | Arcing |
| Item First Ignited | Exterior wall covering or finish |
| Type of Material | Wood or paper, processed, other |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Unspecified short-circuit arc |
Number of Stories With Damage
| Story of Fire Origin | 00 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Undetermined (conversion only) |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |
Sponsored