Report Icon

Incident Report – 06/25/1989
Rr 2, Dodge, Snyder, NE 68664

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On June 25, 1989, Snyder Volunteer Fire Department responded to a fire incident at Rr 2, Dodge, Snyder, NE 68664, an office use, livestock production property.

The alarm was received at 4:15 AM and 25 suppression personnel arrived at 4:30 AM. The time to arrive was 15 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address Rr 2, Dodge, Snyder, NE 68664
County Dodge County
State NE
City Snyder
Zip Code 68664
Mixed Use Office use
Property Use Livestock production
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 15 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received Mutual aid received
Shift 1
Alarms 2
District 008

Personnel


Support Personnel 25
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Snyder Volunteer Fire Department
Department Type Volunteer
Address 502 W 3RD St
Snyder, NE 68664
Phone (402) 568-2612

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key NE_05008_062589_890003_00
State Nebraska
Fire Department ID 05008
Incident Date 06/25/1989
Incident Number 890003
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Natural 2

Legacy Fields


Mutual Aid Yes
Estimated Dollar Loss 180,000
Day of Week Sunday
Time In Service 11:00
Zip Code 68664
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 1
Complex Office complex
Fixed Property Use Piggery, hog production
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Office
Level of Fire Origin 10 to 19 feet above grade
Number of Stories 1
Equipment Involved in Ignition No equipment involved
Form of Heat of Ignition Lightning discharge
Type of Material Ignited Hardboard, plywood
Form of Material Ignited Thermal, acoustical insulation within wall, partition, or floor/ceiling space
Ignition Factor Lightning
Construction Type Unprotected ordinary, not qualifying 5
Extent of Flame Damage Confined to part of room or area of origin
Extent of Smoke Damage Confined to structure or origin
Form of Material Generating Most Smoke Thermal, acoustical insulation within wall, partition, or floor/ceiling space
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Hardboard, plywood
Avenue of Smoke Travel Opening in construction
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 50,000-249,999 dollars
Occupancy Type Single or double occupancy
Occupancy Code BASIC INDUSTRY, UTILITY, DEFENSE: UNCLASSIFIED

Fire Report

Ignition


Heat Source Lightning
Item First Ignited Insulation within structural area
Type of Material Plywood
Cause of Ignition Act of nature
Factor Contributing To Ignition Storm

Number of Stories With Damage


Story of Fire Origin 27

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Garbage, waste, refuse truck
Sponsored