Report Icon

Incident Report – 12/14/1992
Rr Arrowsmith, Arrowsmith, IL 61722

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On December 14, 1992, LeRoy Community Fire Protection District responded to a fire incident at Rr Arrowsmith, Arrowsmith, IL 61722, a grain elevator/silo.

The alarm was received at 8:29 PM and 15 suppression personnel arrived at 8:35 PM. The time to arrive was 6 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address Rr Arrowsmith, Arrowsmith, IL 61722
County McLean County
State IL
City Arrowsmith
Zip Code 61722
Property Use Grain elevator, silo
Census Tract 000000
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received Mutual aid received

Personnel


Support Personnel 15
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name LeRoy Community Fire Protection District
Department Type Volunteer
Address 203 E Cedar St
Le Roy, IL 61752
Phone (309) 962-7401

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key IL_MK293_121492_920041_00
State Illinois
Fire Department ID MK293
Incident Date 12/14/1992
Incident Number 920041
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Service Equip

Legacy Fields


Mutual Aid Yes
Estimated Dollar Loss 1,000
Day of Week Monday
Time In Service 22:15
Zip Code 61722
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Warehouse, storage complex
Fixed Property Use Grain elevators
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Elevator, dumb-waiter
Level of Fire Origin Below ground level or water level
Number of Stories 5
Equipment Involved in Ignition Bearing, brake
Form of Heat of Ignition Heat, spark from friction
Type of Material Ignited Grain, natural fiber (pre-process)
Form of Material Ignited Agricultural product
Ignition Factor Lack of maintenance, worn out
Construction Type Protected Wood Frame
Extent of Flame Damage Confined to the object of origin
Extent of Smoke Damage Confined to room of origin
Form of Material Generating Most Smoke Agricultural product
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Grain, natural fiber (pre-process)
Avenue of Smoke Travel Opening in construction
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 1,000-9,999 dollars
Occupancy Type Single or double occupancy
Occupancy Code STORAGE PROPERTY: UNCLASSIFIED

Fire Report

Ignition


Heat Source Heat, spark from friction
Item First Ignited Agricultural crop, including fruits and vegetables
Type of Material Grain, natural fiber, (preprocess)
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Worn out

Number of Stories With Damage


Story of Fire Origin 51

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Personal aircraft less than 12,500 lb. gross wt

Equipment