Incident Report – 10/06/1993 Rt 11 South Old Green, Mint Spring, VA 24463
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On October 6, 1993, Augusta County Fire & Rescue responded to a fire incident at Rt 11 South Old Green, Mint Spring, VA 24463, a residential use, 1-or-2 family dwelling.
The alarm was received at 12:09 PM and 10 suppression personnel arrived at 12:23 PM. The time to arrive was 14 minutes.
The following action was taken during the incident: identify/analyze hazardous materials.
Sponsored
Location
| Address | Rt 11 South Old Green, Mint Spring, VA 24463 |
| County | Augusta County |
| State | VA |
| City | Mint Spring |
| Zip Code | 24463 |
| Mixed Use | Residential use |
| Property Use | 1 or 2 family dwelling |
| Census Tract | 002800 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 14 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | Mutual aid received |
| Shift | B |
| Alarms | 1 |
| District | 010 |
Personnel
| Support Personnel | 10 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Augusta County Fire & Rescue |
| Department Type | Mostly volunteer |
| Address | 18 Government Center Ln Verona, VA 24482-2639 |
| Phone | (540) 245-5624 |
| Website | https://www.co.augusta.va.us/government/fire-rescue |
Actions Taken
| First Action Taken | Identify, analyze hazardous materials |
Metadata
| Incident Key | VA_01510_100693_329697_00 |
| State | Virginia |
| Fire Department ID | 01510 |
| Incident Date | 10/06/1993 |
| Incident Number | 329697 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Electrical Dist |
Legacy Fields
| Mutual Aid | Yes |
| Estimated Dollar Loss | 500 |
| Day of Week | Wednesday |
| Time In Service | 13:24 |
| Zip Code | 24463 |
| Method of Alarm | Telephone direct to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Remove hazard |
| Number of Aerial Apparatus | 0 |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Function Areas not classified above |
| Level of Fire Origin | Below ground level or water level |
| Number of Stories | 1 |
| Equipment Involved in Ignition | Meter, meter box |
| Form of Heat of Ignition | Unspecified short circuit arc |
| Type of Material Ignited | Plastic not classified above |
| Form of Material Ignited | Electrical wire, cable insulation |
| Ignition Factor | Short circuit, ground fault |
| Construction Type | Unprotected wood frame not qualifying for 7 |
| Extent of Flame Damage | Confined to the object of origin |
| Extent of Smoke Damage | Confined to the object of origin |
| Form of Material Generating Most Smoke | Electrical wire, cable insulation |
| Detector Performance | Detector(s) not in the room or space of fire origin, and they did not operate |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Type of Material Generating Most Smoke | Plastic not classified above |
| Avenue of Smoke Travel | Utility opening in floor |
| Method of Extinguishment | Make-shift aids |
| Property Damage Classification | 100-999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | ONE- AND TWO-FAMILY DWELLING |
Fire Report
Ignition
| Heat Source | Arcing |
| Item First Ignited | Electrical wire, cable insulation |
| Type of Material | Plastic |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Unspecified short-circuit arc |
Structure
| Number of Residential Units | 1 |
Number of Stories With Damage
| Story of Fire Origin | 39 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Rail transport vehicle, other |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |
Sponsored